Mouse SOD1 (Superoxide Dismutase 1, Soluble) ELISA Kit

Mouse SOD1 (Superoxide Dismutase 1, Soluble) ELISA Kit

Size: 96T Price: $420
Reactive Species: Mouse
Assay Range: 0.16-10ng/mL
Sensitivity: 0.09ng/mL
SKU: XEM2099 Category: Mouse Tags: , , , , ,

Datasheet

INFORMATION

Full NameSuperoxide Dismutase 1, Soluble
SynonymALS, ALS1, IPOA, Superoxide dismutase [Cu-Zn]
Assay TypeCompetitive ELISA
ReactivityMouse
Range0.16-10ng/mL
Sensitivity0.09ng/mL
Sample TypeSerum, plasma and other biological fluids
Sample Volume50μL
Detection WavelengthOD450
Reaction Duration1.5h
Transportation Temperature2-8°C
SpecificitySpecifically binds with SOD1, no obvious cross reaction with other analogues.
Microplate96-wells plate breakable into 12 x 8 wells strip

ELISA KIT COMPONENTS

Upon receipt, unpack promptly and store as recommended in the instructions.

ComponentsSpecificationsStorage and Notes
Micro Plate
96T: 8 wells×12 strips
48T: 8 wells×6 strips
Unopened: -20°C, 12 months
Unused: Put it back in the aluminum foil bag and seal it, store it at -20°C.
Reference Standard
96T: 2 vials
48T: 1 vial
Unopened: -20°C, 12 months
Please use freshly dissolved standards for each experiment. Discard any unused standards after dissolution.
Biotinylated Detection Ab Concentrate (100×)
96T: 120μL×1 vial
48T: 60μL×1 vial
Unopened: -20°C, 12 months
Unused: Please seal the concentrate and store it at -20°C, and discard the working solution.
HRP Conjugate Concentrate (100×)
96T: 120μL×1 vial
48T: 60μL×1 vial
Unopened: -20°C(Protect from light), 12 months
Unused: Please seal the concentrate and store it at -20°C, and discard the working solution.
Biotinylated Detection Ab Diluent
14mL×1
2-8℃, 12 months
HRP Conjugate Diluent
14mL×1
2-8℃, 12 months
Reference Standard & Sample Diluent20mL×1
2-8℃, 12 months
Washing Buffer Concentrate (25×)30mL×1
2-8℃, 12 months
Substrate Reagent(TMB)10mL×12-8°C(Protect from light),12 months
Stop Solution7mL×12-8°C/Room temperature

REQUIRED INSTRUMENTS AND REAGENTS

  • Microplate reader (450nm wavelength filter).
  • Incubator capable of maintaining 37℃.
  • 1.5mL EP tube, absorbent paper.
  • Pipette and disposable tip: 0.5-10μL, 2-20μL, 20-200μL, 200-1000μL.
  • Double distilled water or deionized water.

ASSAY PROCEDURE SUMMARY

1
Add 50μL standard or sample to each well, add 50μL Biotinylated Detection Ab working solution to each well. Incubate at 37°C for 45 min.
Washing: Aspirate and wash the plate for 3 times.
2
Add 100μL HRP conjugate working solution.Incubate at 37°C for 30 min.
Washing: Aspirate and wash the plate for 5 times.
3
Add 90μL Substrate Reagent. Incubate at 37℃ for 15 min.
4
Add 50μL Stop Solution.
5
Readings at 450nm. Calculation of results.

STANDARD CURVE

The product has been verified by the quality inspection department and meets the performance requirements of the product manual. (Laboratory temperature: 20-25℃, laboratory relative humidity: 20-60%. Before the experiment, all components were equilibrated to room temperature.) The following data is for reference only. A standard curve must be run with each test.
STD.(ng/mL)OD-1OD-2Average
02.3822.3882.385
0.162.0122.0222.017
0.321.7541.7281.741
0.631.3981.3821.39
1.251.0091.0411.025
2.50.7350.7210.728
50.5140.5560.535
100.4090.4410.425
 Standard Curve Image

RECOVERY

5 different levels of target protein spiked in samples were evaluated for recovery experiments to determine the range of recovery and calculate the average recovery rate.

LINEARITY

5 different levels of target protein spiked in samples were evaluated for recovery experiments to determine the range of recovery and calculate the average recovery rate. Subsequently, the 5 samples were diluted to 2-fold, 4-fold, 8-fold, and 16-fold 10 concentrations, and recovery experiments were performed again to evaluate the range and average recovery rate at different dilution factors.

PRECISION(%)

Intra-assay precision (Precision within an assay): Low, mid range and high levels of the samples were tested 20 times on one plate, respectively.

Inter-assay Precision (Precision between assays): Low, mid range and high levels of the samples were tested on 3 different plates, 20 replicates in each plate, respectively.

ItemIntra-assay PrecisionInter-assay Precision
Sample123123
n202020202020
Mean (ng/mL)0.521.394.670.471.524.22
Standard deviation0.030.080.20.030.090.14
CV(%)6.365.574.365.795.653.37

STABILITY

Perform stability testing of the kit at 37°C and 2-8°C and obtain relevant data.

ELISA kit(n=5)37°C for 1 month2-8°C for 6 months
Average(%)8095-100